Dust is the silent enemy of electronics. We clean server rooms, UPS rooms and raised floors ESD-safe, while the equipment keeps running.
We clean rooms, cabinets and surfaces with ESD-safe agents. No water, no charge, no interruption to the operation.
Under the raised floor runs the cabling and gathers most of the dust. We clean the plenum space without disturbing the airflow.
Every action follows an ESD protocol: earthing, materials and method are matched to keeping sensitive electronics running.
ESD-safe cleaning of rooms and cabinets. Surfaces, cabinets and floors, cleaned while the equipment runs. No water, no charge.
Cleaning of UPS and battery rooms. Dust-free matters most here: heat and dust are a bad combination around batteries and power electronics.
Cleaning of the floor surface. The walkway people and carts cross, cleaned without scratches or charge build-up.
Cleaning of the plenum space. The space under the tiles where the air and cables run, often untouched for years, full of dust.
Working to ESD protocol. Earthing, materials and method matched to sensitive, running electronics. Safe for the equipment.
Cleaning on a fixed schedule. One-off or periodic. We draw up a schedule that fits the contamination level of your room.
Surfaces, cabinets and floors, cleaned while the equipment runs. No water, no charge.
Dust-free matters most here: heat and dust are a bad combination around batteries and power electronics.
The walkway people and carts cross, cleaned without scratches or charge build-up.
The space under the tiles where the air and cables run, often untouched for years, full of dust.
Earthing, materials and method matched to sensitive, running electronics. Safe for the equipment.
One-off or periodic. We draw up a schedule that fits the contamination level of your room.
Four steps, from risk assessment to handover. Everything keeps running, you only notice the result.
We look at the room, the equipment and the airflow, and determine the safe approach.
Work instruction per room, planned at a moment that doesn't touch the operation.
Cleaning while everything runs. Earthed, dust-free, without disturbing the cooling.
Visual inspection and handover. If desired, a periodic schedule for the future.
Call us or request a quote. We clean your room ESD-safe, while everything keeps running.
Supply, installation and replacement of UPS systems and batteries, OEM-independent.
Read more →MO24/7 monitoring of batteries and systems; weak cells caught before failure.
Read more →MAPreventive and corrective maintenance for your critical power.
Read more →LBCommissioning and load testing to full capacity, with a handover file.
Read more →CTCold- and hot-aisle separation for sealed, efficient cooling.
Read more →A response within 24 hours.