First Case positions and installs UPS systems of any brand in data centres, install-ready, for UPS manufacturers and their channel. From UPS installation in a new hall to UPS replacement on a temporary bypass: we plan the work around your uptime. Testing, maintenance and commissioning stay with the manufacturer.
A greenfield build, a new room with no existing installation, or a 1-to-1 replacement of an end-of-life system: we plan the work around the site's uptime, not the other way around. Placement, cabling, and connection, carried out by our own engineers.
For a replacement we set up a temporary bypass: a power path that keeps the load protected while the old system comes out and the new one goes in. The load is never left unprotected. The phasing is worked out in advance, system by system, step by step.
Install-ready is our end point: the system is in position, cabled, and connected, ready for commissioning by the manufacturer or the system builder. Commissioning, bringing the system into service and testing it, stays with the manufacturer. Batteries we cover in full: from change-out, replacing complete battery strings, to monitoring and testing.
White glove treatment: what we bring, we place ourselves. Our own trucks, internal transportation into the server room, and placement in position. The same crew that drives it sets it down: no handover, no unnecessary noise.
From mechanical placement to the complete electrical connection: cabling and tie-in to the backup power supply. Then we hand over install-ready.
Live swap with temporary bypass, so the load is never left unprotected. The old system is removed for certified disposal.
Safe dismantling of systems going out of service. Batteries are removed in line with the rules, including lithium under ADR, the European regulations for transporting hazardous goods by road, with certified recycling through our recycling partner.
White glove treatment: what we bring, we place ourselves. Our own trucks, internal transportation into the server room, and placement in position. The same crew that drives it sets it down: no handover, no unnecessary noise.
From mechanical placement to the complete electrical connection: cabling and tie-in to the backup power supply. Then we hand over install-ready.
Live swap with temporary bypass, so the load is never left unprotected. The old system is removed for certified disposal.
Safe dismantling of systems going out of service. Batteries are removed in line with the rules, including lithium under ADR, the European regulations for transporting hazardous goods by road, with certified recycling through our recycling partner.
Four steps, from survey to handover. Our own engineers, your uptime as the starting point.
We visit the site and survey the route, the room, and the connection. Every brand, every configuration.
Work preparation plans every hour around your uptime. Bypass, phasing, logistics: fixed in advance.
Our own engineers do the work: certified to VCA and NEN 3140, the Dutch standard for safe work on electrical installations, with a fixed ESD protocol against static discharge.
Placed, cabled, and connected: handed over install-ready for commissioning by the manufacturer or the system builder.
12 UPS systems placed and fully DC-cabled in a colocation data centre in the Netherlands, 144 cables of 95 mm², every conductor labelled.
11.600+ batteries replaced across 50+ UPS systems at a data centre in Germany, each block connected to continuous monitoring.
Transport, placement and mechanical installation of two 200 kVA UPS systems with 92 battery blocks at Amsterdam Centraal station, handed over install-ready.
912 batteries replaced across three 1.500 kVA UPS systems, old blocks sent for certified disposal through our recycling partner.
Call us or request a quote. We survey the site, plan around your uptime, and hand over install-ready.
Busbars, power cabling and cable containment (trays and ladders), with our own people.
Read more →BAChange-out, monitoring and testing on assignment, both lead and lithium.
Read more →CTCold and hot aisles separated, to our own design.
Read more →TRWhat we bring in, we also put in place. No handoff.
Read more →WHWe receive, store and deliver to site when it suits the schedule.
Read more →One address, from transport to handover. A response within 24 hours.
Every brand. We work brand-independent: we carry no brand and never buy on speculation, so we have no stake in any brand. We work on behalf of UPS manufacturers and their channel. We survey every site in advance, whatever brand is going in.
Yes, with a live swap. We set up a temporary bypass: a power path that keeps the load protected while the old system comes out and the new one goes in. The load is never left unprotected. The phasing is worked out in advance during work preparation, system by system and step by step.
Install-ready is our end point. The system is in position, cabled and connected to the backup power supply, ready for commissioning by the manufacturer or the system builder. That is where we hand over. Transport into the server room and placement in position we handle ourselves, white glove.
The manufacturer or the system builder. Commissioning, bringing the system into service and testing it, stays with the manufacturer, as does maintenance. We position, install, replace and decommission. Batteries we cover in full, from change-out to testing and monitoring, on assignment.
For UPS manufacturers and their channel: distributors, integrators and installers, and M&E contractors. They outsource the execution to us; we plan the work around the uptime of the site. After installation we hand over install-ready to the manufacturer or the system builder.
We dismantle it safely and remove it for certified disposal. Batteries go with it in line with the rules, including lithium under ADR, the European regulations for transporting dangerous goods by road. Recycling is certified and runs through our recycling partner.